Ihe mgbakwunye ihe dị fechaa | Ndị na-ahụ maka ụfụfụ na-arụ ọrụ dị elu maka ihe nhịahụ cellular
PRAMETERS ngwaahịa
Nkọwa
Overview of 12mm 19mm 24mm pp polypropylene mesh Fibrillated concrete fibre fiber
Maka nguzogide mmetụta dị elu, anyị na-enye Steel Fibers, ezigbo ndochi maka welded waya ntupu na ulo oru ala na tupu nkedo ihe. Anyị na-enyekwa eriri sịntetịtịk Structural pụrụ iche nke na-enye ike tensile dị elu maka ngwa na-achọsi ike. A na-agbasasị eriri ndị a n'otu n'otu n'ime ngwakọta kọmpụta, ịmepụta netwọk nkwado ọtụtụ akụkụ nke usoro ọdịnala na-enweghị ike imezu. Usoro a jikọtara ọnụ na-eme ka owuwu dị mfe, na-eme ka ntinye ngwa ngwa, na enhances n'ozuzu iguzosi ike n'ezi ihe na ogologo ndụ nke ihe, na-enye azịza ọgbara ọhụrụ maka mgbawa mgbawa na ogologo oge.
Features of 12mm 19mm 24mm pp polypropylene mesh Fibrillated concrete fibre fiber
1. Njikwa mgbapeka dị elu yana ịdịte aka emelitere:
Akụkụ bụ isi nke eriri anyị bụ ikike ha nwere ijikọ ma micro-cracks nke na-etolite n'oge steeti plastik yana mgbawa buru ibu na kọmpụta siri ike.. Mgbasa nke akụkụ atọ a na-emepụta matriks na-ejikọta ọnụ nke na-egbochi mgbasa mgbape. Uru a na-enweta kpọmkwem bụ mbelata dị ukwuu na mgbawa plastic shrinkage na obosara ogologo oge. Nke a na-eduga na a ukwuu ọzọ inogide ihe na ala permeability, nke na-eme ka iguzogide mmiri na-abanye, ifriizi-mebie mmebi, na corrosion nke ígwè ọ bụla agbakwunyere. Ihe si na ya pụta bụ nhazi nke nwere ogologo ndụ ọrụ yana belata ụgwọ ọrụ nlekọta.
2. Mmụba Mmetụta yana Mgbochi Abrasion:
eriri, karịsịa ígwè na siri ike sịntetik nnukwu eriri, na-emeziwanye ike nke ihe siri ike na ịrụ ọrụ mgbe mgbawa gasịrị. Ha na-amịkọrọ ma kesaa ike n'elu mmetụta ma ọ bụ ibu. Njirimara a na-enye abamuru nke elu na-agbanwe agbanwe nke na-adịchaghị mfe spalling, chipping, na abrasion n'okpuru oké okporo ụzọ ma ọ bụ n'ibu eyi. Nke a bụ uru dị oke egwu maka ala ụlọ ọrụ mmepụta ihe, pavement ụlọ nkwakọba ihe, na akụrụngwa akụrụngwa, na-eduga n'elu elu na-eyi ihe siri ike nke na-edobe iguzosi ike n'ezi ihe ya ka oge na-aga.
3. Ịrụ ọrụ nke ọma na ego ego:
Otu akụkụ dị mkpa nke iji nkwado eriri bụ mkpochapụ ntupu eriri welded (WWF) n'ọtụtụ ngwa. Nke a na-enye nnukwu uru na saịtị: ọ na-eme ka ntinye dị mfe, n'ihi na enweghị ntupu a ga-edozi ma ọ bụ nwee ike ịkwapụ, na ọ na-eme ka usoro ihe owuwu ahụ dum dịkwuo elu. Site n'iwepụ nzọụkwụ na-akpa ike, oru ngo na-ahụ mbelata ụgwọ ọrụ na usoro iheomume ngwa ngwa. Nkesa otu nke eriri na-eme ka nkwado na-agbanwe agbanwe na mpaghara kọmpụta niile, n'adịghị ka ntupu, nke enwere ike itinye ya n'ụzọ na-ekwesịghị ekwesị, na-eduga na arụmọrụ a pụrụ ịdabere na ya na nke a pụrụ ịkọ.


Specification of 12mm 19mm 24mm pp polypropylene mesh Fibrillated concrete fibre fiber
12mm, 19mm, and 24mm PP Fibrillated Concrete Fibers
Okwu Mmalite ngwaahịa
These fibers are made from 100% polypropylene (PP). They come in three conventional sizes: 12mm , 19mm , and 24mm . The product is fibrillated, which indicates it has a net-like framework that expands inside concrete or mortar. This design aids hold the mix together much better.
Nzuzo gụnyere
The fibers are alkali-resistant , so they last long in cement-based atmospheres. They do not corrosion or corrode like steel fibers. Their surface texture produces solid bonding with the bordering matrix. This boosts the overall toughness of the concrete.
Each fiber is light-weight and easy to mix. It disperses equally without clumping when added throughout batching. Enweghị ngwaọrụ pụrụ iche achọrọ. Simply add the fibers to your regular blending process.
Uru dị na ngwa ngwa
Including these fibers decreases plastic shrinking cracks. They control breaking that happens while the concrete is still fresh. This results in fewer surface issues and much less maintenance later.
They also increase influence resistance and flexural toughness. Ala, okporo ụzọ, and shotcrete advantage most from this support. The fibers act like an additional support system inside the concrete. They link tiny fractures before they enlarge.
Typical Uses
Common applications include industrial floor covering, slabs ụlọ nkwakọba ihe, property driveways, na akụkụ precast. They function well in splashed concrete (shotcrete) for tunnels and slopes. Specialists utilize them in place of bonded wire mesh in lots of light-duty projects.
The 12mm length matches slim overlays and makes. The 19mm dimension helps standard slabs and walls. The 24mm choice provides extra efficiency in heavy-duty or thick sections.
Constantly follow recommended dose prices– na-adịkarị n'etiti 0.6 kg/m atọ na 1.0 n'arọ/m³– relying on the job requires. Proper mixing guarantees full performance.

Applications of 12mm 19mm 24mm pp polypropylene mesh Fibrillated concrete fibre fiber
Applications of 12mm, 19mm, and 24mm PP Fibrillated Concrete Fibers
Concrete siri ike maka ojiji kwa ụbọchị
PP fibrillated fibers made from polypropylene come in three usual lengths: 12mm, 19mm, and 24mm. These fibers mix conveniently right into concrete and assist stop fractures before they start. Building contractors utilize them in many types of tasks since they make concrete tougher without adding much expense.
Where Brief Fibers Function Ideal
Nke 12mm fibers are optimal for thin layers like flooring garnishes, shotcrete, na ogwe precast. They spread out equally through the mix and give excellent surface area defense. You’ll frequently see them in stockroom floorings or auto parking decks where wear resistance issues.
Middle-Length Fibers for General Jobs
19mm fibers supply a balance in between mixing convenience and performance. They work well in walkways, okporo ụzọ, and light-duty pieces. These fibers help control shrinking fractures that happen as concrete dries. Professionals choose them when they need trusted results without special delivery.
Long Fibers for Heavy-Duty Demands
Nke 24mm fibers include extra stamina to thick concrete areas. They are used in industrial floors, ọwara lining, na mgbidi mgbidi. Their longer size assists hold the concrete with each other under stress. This makes them a wise pick for structures that deal with hefty tons or activity.
Ọ dị mfe iji, Ọ na-esiri ike ịkụ
All three dimensions mix straight right into wet concrete with no additional steps. Ha adịghị corrosion, ire ere, or respond with other products. When set, the concrete withstands breaking from drying, mgbanwe ọkwa okpomọkụ, or effect. That indicates fewer repair work and longer life for the finished job. Numerous building contractors currently rely upon these fibers instead of wire mesh due to the fact that they save time and labor while offering consistent outcomes across large puts.
Okwu Mmalite nke ụlọ ọrụ
Nnọọ na Concrete na ndị ọzọ, onye na-eweta ihe mgbakwunye ihe nrụpụta dị elu, gụnyere ndị na-ebelata mmiri konkịtị anyị. Site na ahụmịhe afọ na ahịa zuru ụwa ọnụ, anyị na-enye ihe ngwọta dị elu e mere iji welie àgwà na arụmọrụ nke ọrụ ihe owuwu n'ụwa nile. Ụlọ ọrụ mmepụta ihe ọgbara ọhụrụ anyị na-eme ka ngwaahịa ndị kachasị mma na-agbaso ụkpụrụ mba ụwa. Anyị na-anya isi na ọrụ ndị ahịa pụrụ iche, nkwado ndị teknuzu, na ahaziri ngwọta iji gboo mkpa ọrụ ngo. Soro anyị maka ntụkwasị obi, ọhụrụ, na-eri-irè ihe admixtures na-akpali gị oru ngo na-aga n'ihu. Chọgharịa ọzọ na www.concreteandmore.de/. Ka anyị wulite ọdịnihu ọnụ!
Ọ bụrụ na ị nwere ajụjụ ọ bụla, biko nweere onwe gị ịkpọtụrụ anyị.
Ụzọ ịkwụ ụgwọ
T/T, Western Union, Paypal, Kaadị kredit wdg.
Ụzọ mbupu
Site n'ikuku, site n'oké osimiri, site na nkwuwa okwu, dị ka ndị ahịa na-arịọ.

5 FAQs of 12mm 19mm 24mm pp polypropylene mesh Fibrillated concrete fibre fiber
Frequently Asked Questions About PP Fibrillated Concrete Fibers (12mm, 19mm, 24mm)
What are PP fibrillated fibers used for?
These polypropylene fibers strengthen concrete. Ha na-enyere aka ịchịkwa mgbawa nke ihicha ma ọ bụ mgbanwe okpomọkụ kpatara. Ndị na-ewu ụlọ na-agbakwunye ha na slabs, pavement, na shotcrete. The fibers improve toughness and reduce surface cracking.
Why choose different lengths like 12mm, 19mm, or 24mm?
Each length fits a specific job. Use 12mm fibers in thin layers or plaster. Choose 19mm for standard slabs and floors. Go with 24mm for heavy-duty work like industrial floors or thick sections. Longer fibers give more pull-out resistance.
Kedu eriri eriri ka m ga-agbakwunye na ngwakọta m?
Typical dosage is 0.6–1.0 kg per cubic meter of concrete. Always follow the project specs or supplier advice. Obere obere agaghị enyere aka nke ukwuu. Too much may cause mixing issues or clumping.
Do these fibers replace steel reinforcement?
Mba. PP fibrillated fibers are not a substitute for rebar or wire mesh. Ha na-arụ ọrụ dị ka nkwado nke abụọ. Their main job is to limit early-age plastic shrinkage cracks and boost impact resistance.
Are they easy to mix and place?
Ee. These fibers disperse well in standard mixers. Add them during batching with other materials. Ọ dịghị ngwá ọrụ pụrụ iche achọrọ. They won’t ball up if mixed properly. Finish the surface like regular concrete—no extra steps required.
RỊỌRỌ OKWU
Ngwaahịa ndị metụtara
Direct Concrete nwere nnukwu akụrụngwa akụrụngwa A ọkwa mgbawa na-eguzogide PP Macro Concrete Fiber
Premium Synthetic Fiber PSF Dual Density Polyester Concrete Fiber for Concrete Chemical Staple Virgin Polyester Fiber
Microfiber Concrete 12mm Polypropylene PP Fibrillated Concrete Fiber maka ihe owuwu ụlọ.
hot lower 19 mm ihe pp polypropylene staple eriri si factory
Simenti Polypropylene na-eme ka ihe mgbakwunye ihe mgbakwunye polypropylene fiber sịntetik PP Fiber




















































































