PP Concrete Fiber Fibrillated Mesh maka ihe eji eme ihe na ciment Mortar

PRAMETERS ngwaahịa

Nkọwa
RỊỌRỌ OKWU

Nkọwa

Overview of PP Concrete Fiber Fibrillated Mesh for Concrete and Cement Mortar

Maka nguzogide mmetụta dị elu, anyị na-enye Steel Fibers, ezigbo ndochi maka welded waya ntupu na ulo oru ala na tupu nkedo ihe. Anyị na-enyekwa eriri sịntetịtịk Structural pụrụ iche nke na-enye ike tensile dị elu maka ngwa na-achọsi ike. A na-agbasasị eriri ndị a n'otu n'otu n'ime ngwakọta kọmpụta, ịmepụta netwọk nkwado ọtụtụ akụkụ nke usoro ọdịnala na-enweghị ike imezu. Usoro a jikọtara ọnụ na-eme ka owuwu dị mfe, na-eme ka ntinye ngwa ngwa, na enhances n'ozuzu iguzosi ike n'ezi ihe na ogologo ndụ nke ihe, na-enye azịza ọgbara ọhụrụ maka mgbawa mgbawa na ogologo oge.

Features of PP Concrete Fiber Fibrillated Mesh for Concrete and Cement Mortar

1. Njikwa mgbapeka dị elu yana ịdịte aka emelitere:

Akụkụ bụ isi nke eriri anyị bụ ikike ha nwere ijikọ ma micro-cracks nke na-etolite n'oge steeti plastik yana mgbawa buru ibu na kọmpụta siri ike.. Mgbasa nke akụkụ atọ a na-emepụta matriks na-ejikọta ọnụ nke na-egbochi mgbasa mgbape. Uru a na-enweta kpọmkwem bụ mbelata dị ukwuu na mgbawa plastic shrinkage na obosara ogologo oge. Nke a na-eduga na a ukwuu ọzọ inogide ihe na ala permeability, nke na-eme ka iguzogide mmiri na-abanye, ifriizi-mebie mmebi, na corrosion nke ígwè ọ bụla agbakwunyere. Ihe si na ya pụta bụ nhazi nke nwere ogologo ndụ ọrụ yana belata ụgwọ ọrụ nlekọta.

2. Mmụba Mmetụta yana Mgbochi Abrasion:

eriri, karịsịa ígwè na siri ike sịntetik nnukwu eriri, na-emeziwanye ike nke ihe siri ike na ịrụ ọrụ mgbe mgbawa gasịrị. Ha na-amịkọrọ ma kesaa ike n'elu mmetụta ma ọ bụ ibu. Njirimara a na-enye abamuru nke elu na-agbanwe agbanwe nke na-adịchaghị mfe spalling, chipping, na abrasion n'okpuru oké okporo ụzọ ma ọ bụ n'ibu eyi. Nke a bụ uru dị oke egwu maka ala ụlọ ọrụ mmepụta ihe, pavement ụlọ nkwakọba ihe, na akụrụngwa akụrụngwa, na-eduga n'elu elu na-eyi ihe siri ike nke na-edobe iguzosi ike n'ezi ihe ya ka oge na-aga.

3. Ịrụ ọrụ nke ọma na ego ego:

Otu akụkụ dị mkpa nke iji nkwado eriri bụ mkpochapụ ntupu eriri welded (WWF) n'ọtụtụ ngwa. Nke a na-enye nnukwu uru na saịtị: ọ na-eme ka ntinye dị mfe, n'ihi na enweghị ntupu a ga-edozi ma ọ bụ nwee ike ịkwapụ, na ọ na-eme ka usoro ihe owuwu ahụ dum dịkwuo elu. Site n'iwepụ nzọụkwụ na-akpa ike, oru ngo na-ahụ mbelata ụgwọ ọrụ na usoro iheomume ngwa ngwa. Nkesa otu nke eriri na-eme ka nkwado na-agbanwe agbanwe na mpaghara kọmpụta niile, n'adịghị ka ntupu, nke enwere ike itinye ya n'ụzọ na-ekwesịghị ekwesị, na-eduga na arụmọrụ a pụrụ ịdabere na ya na nke a pụrụ ịkọ.

PP Concrete Fiber Fibrillated Mesh for Concrete and Cement Mortar
PP Concrete Fiber Fibrillated Mesh maka ihe eji eme ihe na ciment Mortar

Specification of PP Concrete Fiber Fibrillated Mesh for Concrete and Cement Mortar

PP Concrete eriri– Fibrillated Mesh Spec

Nchịkọta ihe

PP Concrete Fiber is a fibrillated polypropylene mesh designed for use in concrete and concrete mortar. It adds strength, controls cracking, and boosts longevity. The fibers disperse uniformly during blending and develop a three-dimensional network inside the product.

Atụmatụ igodo

– Emere ya 100% polypropylene na-amaghị nwoke
Fibrillated framework creates high area for much better bonding
Stands up to antacids, kemikal, na mmiri mmiri
Non-corrosive and non-magnetic
Easy to blend with standard batching devices

Ụdị nka nka

Ụdị eriri: Fibrillated polypropylene mesh
Nha: 6 mm na 19 mm (typical choices).
Dayameta (matching): 20– 50 microns.
Ike tensile: ≥ 400 MPa.
Ogologo oge na ezumike: ≥ 15%.
Ihe kpatara Thawing: Odika. 165 Celsius C.
Njupụta: 0.91 g/cm ³.
Agba: White or beige.

Ngwọta akwadoro

Ojiji 0.6– 1.0 n'arọ kwa cubic mita nke ihe ma ọ bụ ngwa agha. Change based on job requirements and performance goals. Higher does might be utilized for improved crack control in thin areas or shotcrete applications.

Uru dị na ngwa

These fibers minimize plastic shrinking splits during early treating. They also enhance effect resistance and strength. The mesh style assists hold the concrete matrix together even after microcracks create. This leads to longer life span and reduced upkeep costs. The fibers function well in slabs, pavement, akụkụ precast, stucco, na idozi ngwa agha.

Ijikwa na ebe nchekwa

Chekwaa na akọrọ kpamkpam, protected area far from direct sunlight. Chekwaa akpa akara mgbe ejighị ya. Enweghị akụrụngwa ejizi pụrụ iche achọrọ– add directly to the mixer with other dry products. Gwakọta ma ọ dịkarịa ala 3– 5 minutes to guarantee complete diffusion.

PP Concrete Fiber Fibrillated Mesh for Concrete and Cement Mortar
PP Concrete Fiber Fibrillated Mesh maka ihe eji eme ihe na ciment Mortar

Applications of PP Concrete Fiber Fibrillated Mesh for Concrete and Cement Mortar

Applications of PP Concrete Fiber Fibrillated Mesh

Ihe Ọ Bụ

PP concrete fiber fibrillated mesh is made from polypropylene. N'oge agwakọta, the mesh breaks into several great fibrils. These fibrils spread uniformly with concrete or cement mortar. This assists regulate cracking and boosts general efficiency.

Ebe ejiri ya mee ihe

This fiber functions well in several usual construction projects. It is typically contributed to floor slabs, both indoors and outdoors. Building contractors utilize it in industrial floorings, Iberibe ụlọ nkwakọba ihe, and parking areas. The fibers help reduce surface area splits caused by drying out and shrinkage.

It is likewise used in shotcrete and splashed concrete applications. Passage linings, incline protection, and retaining wall surfaces benefit from its usage. The mesh improves cohesion and reduces rebound throughout splashing.

For precast aspects like pipelines, na-egbochi, na panel, the fiber adds strength. It aids these items take care of handling and transport without damaging.

Ihe Mere Họrọ Ya

The main reason to use PP fibrillated mesh is split control. Tiny cracks form as concrete dries and diminishes. The fibers hold the material with each other at a micro level. This brings about less visible cracks and better lasting durability.

Fibre anaghị emebi emebi. They resist chemicals and dampness. This makes them safe for usage in damp or aggressive environments.

Adding the mesh is easy. It mixes conveniently with basic devices. Enweghị ngwaọrụ ma ọ bụ ọzụzụ pụrụ iche achọrọ. Just add it during batching like various other completely dry active ingredients.

Mmasị arụmọrụ

Concrete with PP fibrillated mesh shows enhanced impact resistance. It manages abrupt tons much better than plain concrete. Surface area wear additionally reduces, which matters for high-traffic floors.

Workability remains great. The mix remains easy to location and surface. Hemorrhaging and segregation are minimized, causing more consistent outcomes.

This fiber sustains lasting building as well. Much less require for steel reinforcement means reduced carbon influence. It likewise minimizes repair service costs gradually.

Nkọwapụta Ụlọ ọrụ

Anyị bụ ndị ndu zuru ụwa ọnụ na ngwọta ụfụfụ dị fechaa na nke dị elu. Amara ụwa niile maka ntinye aka ya na nyocha, ihe ọhụrụ, na etinyere nka nka, anyị na-enye ihe ngwọta ụfụfụ emepụtara kemgbe mmalite 2012.

Anyị nwere ike na-enye elu-edu ihe admixture na ụfụfụ ihe metụtara ngwaahịa n'ụwa nile.

Ụlọ ọrụ ahụ nwere ngalaba ọkachamara ọkachamara na ngalaba nlekọta àgwà, ụlọ nyocha nke ọma, na kwadebere na elu ule akụrụngwa na mgbe-sales ahịa ọrụ center.

Ọ bụrụ na ị nwere mmasị, biko nweere onwe gị ma kpọtụrụ anyị.

Ịkwụ ụgwọ

T/T, Western Union, Paypal, Kaadị kredit wdg.

Mbupu

Site n'ikuku, site n'oké osimiri, site na nkwuwa okwu, dị ka ndị ahịa na-arịọ.

5 FAQs of PP Concrete Fiber Fibrillated Mesh for Concrete and Cement Mortar

Frequently Asked Questions About PP Concrete Fiber Fibrillated Mesh

What is PP concrete fiber fibrillated mesh?

PP concrete fiber fibrillated mesh is made from polypropylene. N'oge agwakọta, it splits into many fine filaments. These filaments spread evenly through concrete or cement mortar. They help control cracking and improve toughness.

Kedu ihe kpatara eji eriri a na-eme ihe na kọmpụta?

Adding this fiber reduces plastic shrinkage cracks. It also boosts impact resistance and durability. The fibers hold the mix together better, even after small cracks form. This makes the final structure last longer.

Kedu eriri eriri ka m ga-agbakwunye?

Usoro ọgwụgwọ a na-ahụkarị sitere na 0.6 ka 1.2 n'arọ kwa cubic mita nke ihe. Soro ntuziaka onye nrụpụta mgbe niile. Obere ntakịrị nwere ike ọ gaghị enyere aka nke ọma. Nke ukwuu nwere ike ime ka ịgwakọta sie ike ma ọ bụ mee ka ngwakọta ahụ daa.

Can I mix it with other additives?

Ee. PP fibrillated mesh works well with most common concrete additives. This includes water reducers, air entrainers, na superplasticizers. Just add fibers during the normal mixing process. Make sure all materials blend evenly.

Is special equipment needed for mixing?

Enweghị ngwaọrụ pụrụ iche achọrọ. Standard ihe mixers na-arụ ọrụ nke ọma. Add fibers early in the mixing cycle. Mix maka opekata mpe 3 ka 5 minutes to ensure full dispersion. Good mixing prevents clumping and gives consistent results.

RỊỌRỌ OKWU

RỊỌRỌ OKWU