Graphene Aerogel Graphitization Induction Heat Treatment Vacuum Lab Furnace

PARAMETER PRODUK

Katrangan
Njaluk QUOTE

Katrangan

Overview of Graphene Aerogel Graphitization Induction Heat Treatment Vacuum Lab Furnace

Graphene Aerogel Graphitization Induction Heat Treatment Vacuum Lab Furnace is a synthetic porous ultralight material derived from a gel, ing ngendi komponen cair wis diganti karo gas. Asil punika ngalangi karo Kapadhetan banget kurang lan konduktivitas termal kurang, asring diceluk “kumelun beku.” Senadyan katon rapuh, bisa direkayasa dadi kuwat banget, nyekeli gelar bahan padhet insulating paling apik ing donya.

Features of Graphene Aerogel Graphitization Induction Heat Treatment Vacuum Lab Furnace

  • Konduktivitas termal paling murah ing donya: Nyedhiyakake kinerja jampel unparalleled, luwih unggul tinimbang bahan tradisional.

  • Kapadhetan banget Low: Salah sawijining bahan padhet sing paling entheng sing dikenal manungsa, kanthi komposisi nganti 99.8% hawa.

  • Area lumahing dhuwur: Nduwe area permukaan internal sing luar biasa gedhe, nggawe terkenal kanggo aplikasi filtrasi lan panyerepan.

  • Komposisi Versatile: Bisa digawe saka macem-macem bahan, kalebu silika, karbon, lan oksida logam, saben duwe sifat unik.

  • Porositas luar biasa: Struktur nanoporous tanggung jawab kanggo kemampuan insulasi sing luar biasa.

    Lapisan Airgel

Graphene Aerogel Graphitization Induction Heat Treatment Vacuum Lab Furnace
Graphene Aerogel Graphitization Induction Heat Treatment Vacuum Lab Furnace

Specifications of Graphene Aerogel Graphitization Induction Heat Treatment Vacuum Lab Furnace

Graphene Aerogel Graphitization Induction Warmth Treatment Vacuum Cleaner Lab Heating System– Spesifikasi Teknis

Heater

This lab heating system utilizes high-frequency induction heating. It reaches temperature levels approximately 3000 ° C . The system warms samples promptly and equally. Power input is 100– 250 kW , adjustable based on process demands. Temperature control precision stays within ± 5 ° C

. Vacuum cleaner Efficiency

The chamber operates under high vacuum conditions. Base stress reaches ≤ 5 × 10 ⁻³ . A two-stage pumping system consists of a mechanical pump and a diffusion pump. Optional turbo-molecular pumps are available for faster emptying. Leak rate is less than 5 × 10 ⁻⁴ Pa · L/s .

Chamber Layout

The primary chamber is made of stainless steel 304 . Internal measurements are Φ300 mm × 400 mm (H). Water-cooled copper coils surround the chamber for secure induction. All seals use metal gaskets to keep ultra-high vacuum integrity.

Control System

An industrial PLC manages all procedures. The interface features a 10-inch shade touchscreen . Individuals can set heating contours, vacuum cleaner levels, and gas flow rates. Data logs conserve automatically. Safety interlocks quit operation if stress or temperature level surpasses limits.

Ambience Control

The heater sustains inert gas backfilling (argon or nitrogen). Gas circulation is exactly metered through mass circulation controllers. Maximum working stress during gas mode is 0.1 MPa . Exhaust gases pass through a filtration unit prior to release.

Cooling & Keamanan

A closed-loop water cooling system shields coils and chamber wall surfaces. Circulation sensing units monitor coolant in actual time. Emergency situation power cutoff triggers throughout overheating or water failure. The external shell stays below 45 ° C during full operation.

Power & Setup

Input voltage: 380 V, 3-fase, 50/60 Hz . Total weight: 2500 kg . Flooring area needed: 2.5 m × 1.8 m . Consists of casters for simple relocation. Full installation support and operator training are supplied.

Graphene Aerogel Graphitization Induction Heat Treatment Vacuum Lab Furnace
Graphene Aerogel Graphitization Induction Heat Treatment Vacuum Lab Furnace

Applications of Graphene Aerogel Graphitization Induction Heat Treatment Vacuum Lab Furnace

Applications of Graphene Aerogel Graphitization Induction Warm Treatment Vacuum Cleaner Lab Heating System

Exact Warm Control for Advanced Products

This vacuum cleaner laboratory furnace uses induction home heating to deal with graphene aerogel under heats. It produces a clean, oxygen-free setting. That stops oxidation and keeps the material pure throughout processing. The system warms up quick and holds temperature level really stable. This is essential when turning graphene aerogel right into very gotten graphite frameworks.

High-Quality Graphitization

Graphene aerogel starts as a light-weight, permeable material. After warm treatment in this furnace, its carbon atoms reposition right into a more secure, crystalline type. The result is graphitized aerogel with much better electrical conductivity, thermal security, and mechanical stamina. Scientists use this process to tweak product homes for certain uses.

Ideal for R & D

Labs working on power storage, sensors, or aerospace materials rely upon this heating system. It helps evaluate exactly how various heating rates, hold times, and vacuum degrees impact the final product. The style enables fast arrangement and repeatable outcomes. Individuals can run small batches without wasting time or resources.

Tidy and Safe Procedure

The secured vacuum chamber stops outside air from getting in. Cooling down takes place inside the exact same chamber, so the example remains shielded. Security functions include automated shutoffs and real-time surveillance. Operators get constant outcomes with marginal risk.

Developed for Demanding Jobs

Every component of the furnace is made to manage severe heat and repeated usage. The induction coil provides also heating throughout the example. Temperature level control is exact to within a couple of degrees. This level of precision matters when collaborating with nanomaterials like graphene aerogel.

Profil Perusahaan

Kita minangka pimpinan global ing beton ringan lan solusi busa rekayasa canggih. Dikenal sacara global amarga komitmen kanggo riset, inovasi, lan keahlian sing ditrapake, kita wis nyediakake solusi umpluk direkayasa wiwit awal 2012 kang.

Kita bisa nyuplai campuran beton berkualitas tinggi lan produk sing gegandhengan karo beton busa ing saindenging jagad.

Perusahaan iki nduweni departemen teknis profesional lan departemen pengawasan kualitas, laboratorium sing dilengkapi kanthi apik, lan dilengkapi peralatan testing majeng lan pusat layanan customer sawise-sales.

Yen sampeyan kasengsem, please aran gratis lan hubungi kita.

pambayaran

T/T, Western Union, Paypal, Kertu kredit etc.

Kintunan

Miturut udhara, dening segara, kanthi ekspres, minangka request pelanggan.

Graphene Aerogel Graphitization Induction Heat Treatment Vacuum Lab Furnace
Graphene Aerogel Graphitization Induction Heat Treatment Vacuum Lab Furnace

5 FAQs of Graphene Aerogel Graphitization Induction Heat Treatment Vacuum Lab Furnace

Pitakonan sing Sering Ditakoni

What is this furnace used for?

This furnace heats graphene aerogel under vacuum using induction. It helps turn the aerogel into a more stable, conductive form through graphitization. Researchers and labs use it to improve material performance for batteries, sensors, and other advanced applications.

Why use induction heating instead of other methods?

Induction heating works fast and heats the material evenly from the inside. It gives better control over temperature and avoids contamination. This matters a lot when working with sensitive nanomaterials like graphene aerogel.

Can the furnace run under full vacuum?

ya wis. The system maintains high vacuum levels during the whole heat treatment process. This prevents oxidation and keeps the graphene structure clean and intact. Vacuum also supports consistent graphitization results.

What temperature range does it support?

The furnace can reach up to 2800°C. This high range is needed to fully graphitize aerogel. Users can set and hold any temperature within this range with high precision.

Is the system easy to operate?

ya wis. It comes with a user-friendly control panel and pre-set programs for common processes. Safety features like overheat protection and vacuum interlocks are built in. Most users get trained and start running tests within a day.

Njaluk QUOTE

Njaluk QUOTE