Mga Foamed Concrete Cracking at Shrinkage Solutions

The shrinkage, cracking and water absorption of foamed concrete are three closely related problems.Sa pangkalahatan, foamed concrete due to poor early maintenance, water conservation measures are not enough or in the use process conditions are more stringent, will cause its internal moisture evaporation, resulting in volume shrinkage, cracking or significant water absorption.And foam concrete absorbs water too much to be able to reduce heat preservation heat insulation effect again.From the preparation process of foamed concrete and the observation and study on the section of hardened body, it is found that most of the holes in the foamed concrete are relatively independent closed holes. Samakatuwid, the well-preserved foamed concrete is soaked in water, and its water absorption is mainly concentrated in the surface layer, but does not have great water absorption.The main factors affecting the shrinkage, cracking and water absorption of foamed concrete are as follows:



1. Impluwensya ng dosis ng semento

In the process of hydration and hardening, the solid volume of ordinary Portland cement increases, habang ang semento + lumiliit ang sistema ng tubig.Pangalawa, the hydration process of cement is also accompanied by thermal effect, causing initial volume expansion and cooling and shrinkage, na nagreresulta sa pagtaas ng maliwanag na pag-urong.Bilang karagdagan, there is a phenomenon of selfshrinkage caused by water absorption in the process of cement hydration.Samakatuwid, sa pangkalahatan, if other conditions are basically the same, the amount of cement increases, the shrinkage of foam concrete will increase accordingly.Cement is also one of the important factors to ensure the strength, kaya mayroong angkop na hanay ng dosis ng semento.


2. The influence of cement types

Not all cement before and after the hardening of the volume is shrinkage, expansion of cement before and after the hardening of the volume is not shrinkage but expansion.Samakatuwid, if appropriate expansion cement is adopted, the overall shrinkage of foamed concrete can be compensated or reduced to a certain extent.Gayunpaman, expansion cement not only affects the volume change, but also affects a series of other properties, too much introduction will cause damage to the structure of hardened foam concrete, so the variety and dosage of expansion cement must be determined through the test.


3. Influence of aggregate

Foamed concrete can only be mixed with a part of fine aggregate, because of the chemical inertia of aggregate, excessive mixing will lead to a significant reduction in the strength of foamed concrete, so its content is limited to a certain extent.When the density, water-cement ratio and other technological parameters of foamed concrete are basically determined, the amount of cement will decrease as the fine aggregate increases. Samakatuwid, there is an appropriate choice between whether to mix the aggregate or not and how much.


4. Influence of water-cement ratio and conservation system

The molding water-cement ratio of foam concrete is often as high as 0.7 o kahit na 0.8, and the excess water will remain in the pores of hardened foam concrete, which accounts for about 50% of the molding water.When ambient relative humidity is low or ambient temperature is high, water evaporates and escapes.Lalo na sa maagang yugto ng hardening, medyo mahina pa rin ang structure ng foamed concrete, if the maintenance is not good, water loss is extremely easy, leading to greater shrinkage and surface cracking, weaken the internal structure of the hardening body, leading to high water absorption of hardened foam concrete.Samakatuwid, the initial water-cement ratio of foamed concrete becomes a precondition for the shrinkage of hardened foamed concrete.One of the key techniques to prepare low shrinkage foamed concrete is to control low water cement ratio.


5. Technical approach to reduce shrinkage and cracking of foamed concrete

Ayon sa pagsusuri sa itaas, the technical measures to reduce the shrinkage, prevent cracking and water absorption of foam concrete mainly include the following aspects:

(1) appropriate cement dosage;

(2) add appropriate expansion cement;

(3) low molding water-cement ratio;

(4) optimize the maintenance system and strengthen early water conservation;

(5) use waterproof agent (mixing or surface coating).

Ang Cie-China.org ay ang nangungunang provider ng foam concrete additives na nagbibigay ng concrete foaming agent, superplasticizer,foam concrete strength enhancer para sa magaan na kongkreto, Mga bloke ng CLC. Kung hinahanap mo superplasticizer, mangyaring huwag mag-atubiling makipag-ugnayan sa amin.